All Powered components of an item are taken into account in grid power/load calculations, not just the first one
This commit is contained in:
@@ -127,45 +127,48 @@ namespace Barotrauma.Items.Components
|
||||
|
||||
if (it.Condition <= 0.0f) continue;
|
||||
|
||||
Powered powered = it.GetComponent<Powered>();
|
||||
if (powered == null || !powered.IsActive) continue;
|
||||
|
||||
if (connectedList.Contains(powered)) continue;
|
||||
|
||||
PowerTransfer powerTransfer = powered as PowerTransfer;
|
||||
if (powerTransfer != null)
|
||||
foreach (Powered powered in it.GetComponents<Powered>())
|
||||
{
|
||||
powerTransfer.CheckJunctions(deltaTime);
|
||||
continue;
|
||||
}
|
||||
|
||||
PowerContainer powerContainer = powered as PowerContainer;
|
||||
if (powerContainer != null)
|
||||
{
|
||||
if (recipient.Name == "power_in")
|
||||
if (powered == null || !powered.IsActive) continue;
|
||||
|
||||
if (connectedList.Contains(powered)) continue;
|
||||
|
||||
PowerTransfer powerTransfer = powered as PowerTransfer;
|
||||
if (powerTransfer != null)
|
||||
{
|
||||
fullLoad += powerContainer.CurrPowerConsumption;
|
||||
powerTransfer.CheckJunctions(deltaTime);
|
||||
continue;
|
||||
}
|
||||
|
||||
PowerContainer powerContainer = powered as PowerContainer;
|
||||
if (powerContainer != null)
|
||||
{
|
||||
if (recipient.Name == "power_in")
|
||||
{
|
||||
fullLoad += powerContainer.CurrPowerConsumption;
|
||||
}
|
||||
else
|
||||
{
|
||||
fullPower += powerContainer.CurrPowerOutput;
|
||||
}
|
||||
}
|
||||
else
|
||||
{
|
||||
fullPower += powerContainer.CurrPowerOutput;
|
||||
}
|
||||
}
|
||||
else
|
||||
{
|
||||
connectedList.Add(powered);
|
||||
//positive power consumption = the construction requires power -> increase load
|
||||
if (powered.CurrPowerConsumption > 0.0f)
|
||||
{
|
||||
fullLoad += powered.CurrPowerConsumption;
|
||||
}
|
||||
else if (powered.CurrPowerConsumption < 0.0f)
|
||||
//negative power consumption = the construction is a
|
||||
//generator/battery or another junction box
|
||||
{
|
||||
fullPower -= powered.CurrPowerConsumption;
|
||||
connectedList.Add(powered);
|
||||
//positive power consumption = the construction requires power -> increase load
|
||||
if (powered.CurrPowerConsumption > 0.0f)
|
||||
{
|
||||
fullLoad += powered.CurrPowerConsumption;
|
||||
}
|
||||
else if (powered.CurrPowerConsumption < 0.0f)
|
||||
//negative power consumption = the construction is a
|
||||
//generator/battery or another junction box
|
||||
{
|
||||
fullPower -= powered.CurrPowerConsumption;
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||